OXWELD PM-100,200,300 & GST Series Tips

ESAB

OXWELD PM-100,200,300 & GST Series Tips

The following items have been added to your list


x

PM-100, 200, 300 & PM-GST mechanized torches mix preheat oxygen and preheat fuel gas outside the tip; maximum flashback resistance and comfortable 4-6" standoff from tip to work piece (Note: cannot pierce due to post mixing design)

BUY NOW


Features

  • 4-6" standoff cutting height
  • PM-100 capacity: 16 in.
  • PM-200 capacity: 24 in.
  • PM-300 capacity: 40 in.
  • PM-GST capacity: 16 in.


Industries

  • Industrial and General Fabrication
  • Structural Steel Fabrication
  • Repair and Maintenance
  • Light Fabrication
OXWELD PM-100,200,300 & GST Series Tips

Documents


Gas Tips

Conditional Statement Fits PM-100, 200, & GST Torches
Metal Thickness 3 to 6 in.
Conditional Statement Fits PM-100, 200, & GST Torches
Metal Thickness 6 to 10 in.
Conditional Statement Fits PM-100, 200, & GST Torches
Metal Thickness 6 to 10 in.
Conditional Statement Fits PM-100, 200, & GST Torches
Metal Thickness 10 to 16 in.
Conditional Statement Fits PM-100, 200, & GST Torches
Metal Thickness 10 to 24 in.
Conditional Statement Fits PM-100, 200, & GST Torches
Metal Thickness 4 to 9 in.
Conditional Statement Fits PM-300 Torches
Metal Thickness 20 to 30 in.
Conditional Statement Fits PM-300 Torches
Metal Thickness 30 to 40 in.

Gas Tips Fuel Data

Conditional Statement PM - GST Operating Data
Gas Pressure - Cutting Oxygen 80-110 psig
Gas Pressure - Propane/NatGas 10-30 psig
Part Number 2118700
Total Oxygen Consumption 2,080 cfh
Total Propane/NaturalGas Consumption 225-500 cfh
Conditional Statement PM - GST Operating Data
Gas Pressure - Cutting Oxygen 80-110 psig
Gas Pressure - Propane/NatGas 10-30 psig
Part Number 2118701
Total Oxygen Consumption 1,640 cfh
Total Propane/NaturalGas Consumption 225-500 cfh
Conditional Statement PM - GST Operating Data
Gas Pressure - Cutting Oxygen 80-110 psig
Gas Pressure - Propane/NatGas 10-30 psig
Part Number 2118702
Total Oxygen Consumption 1,260 cfh
Total Propane/NaturalGas Consumption 225-500 cfh
Conditional Statement PM-100/200
Gas Pressure - Cutting Oxygen 85 psig
Gas Pressure - Preheat Oxygen 10-20 psig
Gas Pressure - Propane/NatGas 4-6 psig
Part Number 2118700
Total Oxygen Consumption 1800 cfh
Total Propane/NaturalGas Consumption 180-240 cfh
Conditional Statement PM-100/200
Gas Pressure - Cutting Oxygen 85 psig
Gas Pressure - Preheat Oxygen 10-20 psig
Gas Pressure - Propane/NatGas 4-6 psig
Part Number 2118701
Total Oxygen Consumption 1400 cfh
Total Propane/NaturalGas Consumption 180-240 cfh
Conditional Statement PM-100/200
Gas Pressure - Cutting Oxygen 85 psig
Gas Pressure - Preheat Oxygen 10-20 psig
Gas Pressure - Propane/NatGas 4-6 psig
Part Number 2118702
Total Oxygen Consumption 1020 cfh
Total Propane/NaturalGas Consumption 180-240 cfh
Conditional Statement PM-100/200
Gas Pressure - Cutting Oxygen 135 psig
Gas Pressure - Preheat Oxygen 10-20 psig
Gas Pressure - Propane/NatGas 4-6 psig
Part Number 2118703
Total Oxygen Consumption 3040 cfh
Total Propane/NaturalGas Consumption 180-240 cfh
Conditional Statement PM-100/200
Gas Pressure - Cutting Oxygen 190 psig
Gas Pressure - Preheat Oxygen 10-20 psig
Gas Pressure - Propane/NatGas 4-6 psig
Part Number 2118707
Total Oxygen Consumption 2020 cfh
Total Propane/NaturalGas Consumption 180-240 cfh
Conditional Statement PM-300
Gas Pressure - Cutting Oxygen 50 psig
Gas Pressure - Preheat Oxygen 10-20 psig
Gas Pressure - Propane/NatGas 4-6 psig
Part Number 2228184
Total Oxygen Consumption 4600 cfh
Total Propane/NaturalGas Consumption 180-240 cfh
Conditional Statement PM-300
Gas Pressure - Cutting Oxygen 80 psig
Gas Pressure - Preheat Oxygen 10-20 psig
Gas Pressure - Propane/NatGas 4-6 psig
Part Number 2228185
Total Oxygen Consumption 3800 cfh
Total Propane/NaturalGas Consumption 180-240 cfh
Conditional Statement PM-300
Gas Pressure - Cutting Oxygen 135 psig
Gas Pressure - Preheat Oxygen 10-20 psig
Gas Pressure - Propane/NatGas 4-6 psig
Part Number 2228186
Total Oxygen Consumption 5200 cfh
Total Propane/NaturalGas Consumption 180-240 cfh

Operating Specifications

Conditional Statement PM - GST Operating Data
Metal Thickness 10 to 16 in.
Part Number 2118700
Stand Off 4-6 in.
Conditional Statement PM - GST Operating Data
Metal Thickness 6 to 10 in.
Part Number 2118701
Stand Off 4-6 in.
Conditional Statement PM - GST Operating Data
Metal Thickness 3 to 6 in.
Part Number 2118702
Stand Off 4-6 in.
Conditional Statement PM-100/200
Metal Thickness 10 to 20 in.
Part Number 2118700
Stand Off 4-6 in.
Conditional Statement PM-100/200
Metal Thickness 6 to 10 in.
Part Number 2118701
Stand Off 4-6 in.
Conditional Statement PM-100/200
Metal Thickness 3 to 6 in.
Part Number 2118702
Stand Off 4-6 in.
Conditional Statement PM-100/200
Metal Thickness 20 to 30 in.
Part Number 2118703
Stand Off 4-6 in.
Conditional Statement PM-100/200
Metal Thickness 6 to 10 in.
Part Number 2118707
Stand Off 4-6 in.
Conditional Statement PM-300
Metal Thickness 20 to 30 in.
Part Number 2228184
Stand Off 5-7 in.
Conditional Statement PM-300
Metal Thickness 20 to 30 in.
Part Number 2228185
Stand Off 5-7 in.
Conditional Statement PM-300
Metal Thickness 30 to 40 in.
Part Number 2228186
Stand Off 5-7 in.

Extra Info

Oxygen pressure: Set while cutting lever is depressed; pressure measured at the torch.~~Natural gas or propane pressure: Set while cutting lever is depressed and fuel gas valve is wide open; pressure measured at the torch.

x

Part Numbers and Accessories

Part Numbers : OXWELD PM-100,200,300 & GST Series Tips
PM-110-200 Alternate Fuel Tip 2118707 FIND A DISTRIBUTOR
PM-120-85 Alternate Fuel Tip 2118702 FIND A DISTRIBUTOR
PM-140-85 Alternate Fuel Tip 2118701 FIND A DISTRIBUTOR
PM-160-135 Alternate Fuel Tip 2118703 FIND A DISTRIBUTOR
PM-160-85 Alternate Fuel Tip 2118700 FIND A DISTRIBUTOR
PM-228-135 Alternate Fuel Tip* 2228186 FIND A DISTRIBUTOR
PM-228-85 Alternate Fuel Tip* 2228185 FIND A DISTRIBUTOR
x
x

x

Loading..